BQKJP - BA-3036 ALKALINE BATTERY/CELL

  • MSDS: BQKJP
  • Manufacturer: BREN TRONICS INC
  • Product Name: BA-3036 ALKALINE BATTERY/CELL
  • National Stock Number: 6135-00-935-2589
Product Identification

Product ID:BA-3036 ALKALINE BATTERY/CELL
MSDS Date:03/01/1991
FSC:6135
NIIN:00-935-2589
MSDS Number: BQKJP

Responsible Party
BREN-TRONICS INC
10 BRAYTON CT
COMMACK, NY 11725-3104
US

Emergency Phone: 516-499-5155

Info Phone: 516-499-5155

Cage: 51828

Contractor
BREN-TRONICS INC
COMMACK, NY 11725-3104 US

Telephone: 631-499-5155

Cage: 51828

Ingredients

POTASSIUM HYDROXIDE

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 5-9%

OSHA PEL 2 MG/CUM (CEILING)

ACGIH TLV: 2 MG/CUM (CEILING)

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


MANGANESE DIOXIDE

CAS: 1313-13-9

RTECS: OP0350000

Fraction By Weight: 32-38%

OSHA PEL 5 MG/CUM

ACGIH TLV: 5 MG/CUM (MN)


ZINC

CAS: 7440-66-6

RTECS: ZG8600000

Fraction By Weight: 11-16%

ACGIH TLV: 10 MG/CUM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


MERCURY, QUICKSILVER

CAS: 7439-97-6

RTECS: OV4550000

Fraction By Weight: <1%

OSHA PEL 0.1 MG/CUM (SKIN)

ACGIH TLV: 0.01 MG/CUM (SKIN)

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: IRRITATION OR BURNS. EYES: BURNS
& PERMANENT INJURY.
Explanation of Carcinogenicity:NONE

First Aid

First Aid:SKIN: FLUSH W/WATER & WASH W/SOAP & WATER. EYES: FLUSH
W/PLENTY OF WATER FOR 15 MINS. OBTAIN MEDICAL ATTENTION IN ALL
CASES.

Fire Fighting

Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE A SCBA WHEN A LARGE
NUMBER OF CELLS ARE INVOLVED.
Unusual Fire/Explosion Hazard:CELLS MAY RUPTURE WHEN HEATED
EXCESSIVELY; MAY RELEASE TOXIC MERCURY & CORROSIVE MATERIALS WHEN
INTEGRITY OF CELL CAN IS BROKEN.

Accidental Release

Spill Release Procedures:COLLECT ALL RELEASED MATERIAL IN PLASTIC BAG
FOR WASTE DISPOSAL.

Handling

Handling and Storage Precautions:STORE IN DRY PLACE. DON'T RECHARGE,
SHORT CIRCUT, DISASSEMBLE OR HEAT. USE BATTERY ONLY IN PROPER
EQUIPMENT.
Other Precautions:AVOID SKIN & EYE CONTACT OR BREATHING OF VAPORS.
OBSERVE CORRECT POLARITY WHEN INSTALLING INTO EQUIPMENT.

Exposure Controls

Respiratory Protection:USE SELF CONTAINED BREATHING APPARATUS.
Protective Gloves:RECOMMENDED
Supplemental Safety and Health

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEAT
Hazardous Decomposition Products:HAZARDOUS VAPORS OF MERCURY OR CAUSTIC
POTASSIUM HYDROXIDE

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, &
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.